Outage category: Applications
Location: All users of Canvas
Status: Closed
Resolved Alert: Mon, August 31, 2026 7:44 pm
Initial Symptoms
Users reported pages slow to load or were temporarily inaccessible
Root Cause Analysis
Cause
A surge of automated background requests used up the connections Canvas keeps open to its databases. As those connections filled, our traffic router began treating healthy servers as failed and funneling their traffic onto fewer and fewer zones, making congestion worse with each round. Engineers added database and connection capacity to break the cycle.
Resolution
Instructure Engineers added application servers at 12:19 pm MDT to spread the load. At 12:36 pm MDT our cloud provider confirmed the network and servers were healthy, meaning the servers our own health checks had marked as failing were fine. That turned the investigation back to Canvas itself. We deployed a larger database instance at 12:56 pm MDT and added database capacity at 1:10 pm MDT.
The backlog of waiting requests began clearing at 1:13 pm MDT, and routing adjustments across the main load balancers followed between 1:18 pm MDT and 1:34 pm MDT. Intermittent errors continued while connection queues stayed full, so at 2:09 pm MDT engineers tripled the capacity of the database connection balancers. That cleared the queues, and performance returned to normal at 2:14 pm MDT.
Prevention
From Instructure: We increased database replica capacity, adjusted load balancer settings, and tripled the size of the database connection balancers. That cleared the backlog and restored steady performance. We’re reviewing how Canvas manages database connections and how traffic is balanced across zones, so congestion in one place can’t cascade the way it did here.